(858) 224-9100
PCR Plates
96-well and 384-well PCR plates in standard and low-profile heights. Full-skirted, semi-skirted, and unskirted options for every thermal cycler and automation platform.


96-Well PCR Plate, Semi Skirted, Low Profile, 0.1mL, 50/unit
SKU: PCV-96-0201


96-Well PCR Plate, Sub-Semi Skirted, Low Profile, 0.1mL, 50/unit
SKU: PCV-96-0301


384-Well PCR Plate, Skirted, 40uL, 50/unit
SKU: PCW-38-0404
PCR Plates for Every Workflow
Our PCR plates are manufactured from ultra-thin, uniform-wall virgin polypropylene for optimal thermal transfer and consistent well-to-well amplification. Available in white (for qPCR fluorescence) and clear (for endpoint PCR), with options for barcoding and automation compatibility.
Full-skirted vs. semi-skirted vs. unskirted
| Skirt Type | Rigidity | Automation | Best For |
|---|---|---|---|
| Full-Skirted | Highest — rigid frame | Robotic grippers, plate stackers | Automated liquid handling, high-throughput qPCR |
| Semi-Skirted | Medium — partial frame | Most thermal cyclers | General PCR, manual and semi-automated workflows |
| Unskirted | Flexible | Block-only cyclers | Budget-friendly endpoint PCR, fits directly in block |
Standard-profile plates (~15.5 mm well height, ~200 µL max volume) are the default for most thermal cyclers. Low-profile plates (~10.8 mm well height, ~100 µL max volume) are required for instruments with reduced-height lids, including many real-time PCR systems (e.g., Bio-Rad CFX, Roche LightCycler). Check your instrument manual before ordering.
Use white plates for qPCR—the opaque walls reflect fluorescent signal back toward the detector, increasing sensitivity by 2–4x compared to clear plates. Use clear plates for endpoint PCR where you only need to visualize amplicons on a gel.
PCR Plate FAQ
The Bio-Rad CFX96 requires low-profile 96-well plates (semi-skirted or unskirted) with a compatible optical seal. Our low-profile semi-skirted plates with optical adhesive film are a validated combination for this instrument.
Yes. Our full-skirted plates conform to SBS/ANSI microplate standards and are compatible with Hamilton, Tecan, Beckman, and Eppendorf robotic platforms. Barcoded versions are available for LIMS tracking.
PCR plates are designed for thermal cycling, not long-term storage. For sample storage at −80°C, use our deep-well plates or storage plates with pierceable sealing mats that prevent evaporation.
For qPCR, use optical adhesive film or optically clear heat-seal foil. For endpoint PCR, strip caps or standard adhesive film work well. Foil seals are best when plates will be stored or transported before analysis.
Yes. Our 384-well plates are available in standard profile for high-throughput screening and miniaturized qPCR. They reduce reagent consumption by 75% compared to 96-well format while maintaining amplification performance.