Membrane Filters
Disc membrane filters for vacuum and pressure-driven filtration. Available in PTFE, Nylon, PES, PVDF, MCE, and glass fiber across standard diameters and pore sizes.


Vacuum Filter Flask, PES, Sterile, 0.22um, 150mL, 12/unit
SKU: FFC-10-0150


Vacuum Filter Flask, PES, Sterile, 0.22um, 250mL, 12/unit
SKU: FFC-10-0250


Vacuum Filter Flask, PES, Sterile, 0.22um, 500mL, 12/unit
SKU: FFC-10-0500


Vacuum Filter Flask, PES, Sterile, 0.22um, 1000mL, 12/unit
SKU: FFC-10-1000


Vacuum Filter Flask, PES, Sterile, 0.45um, 500mL, 12/unit
SKU: FFC-20-0500
Choosing the Right Membrane Filter
Membrane disc filters are used in vacuum filtration assemblies, syringe filter holders, and air monitoring cassettes. The membrane material determines chemical compatibility, while pore size determines the particle retention cutoff. Matching both to your application is critical for reliable filtration results.
Membrane Materials at a Glance
| Membrane | Chemistry | Best For | Avoid |
|---|---|---|---|
| PTFE | Hydrophobic | Aggressive solvents, acids, bases, air/gas filtration | Aqueous solutions (requires pre-wetting) |
| Nylon | Hydrophilic | Aqueous and organic HPLC mobile phases | Strong acids (< pH 3) |
| PES | Hydrophilic, low binding | Protein solutions, tissue culture media, biological buffers | Organic solvents |
| PVDF | Low protein binding | Protein-containing samples, Western blot transfers | DMSO, DMF |
| MCE | Hydrophilic | Aqueous solutions, sterility testing, particle analysis | Most organic solvents |
| Glass Fiber | Depth filter | Pre-filtration, high-particulate samples, gravimetric analysis | HF acid |
For heavily particulate samples, layer a glass fiber prefilter on top of your membrane in the filtration assembly. This prevents premature clogging of the membrane and extends throughput. Glass fiber discs with 1.0 µm retention make effective prefilters for 0.2–0.45 µm membranes.
Membrane Filter FAQ
Use 0.2 µm (0.22 µm) for sterilization of buffers, media, and solutions. This pore size retains bacteria and most microorganisms. Note that 0.2 µm membranes do not remove mycoplasma or viruses.
0.22 µm is the standard for sterilizing filtration and UHPLC sample prep. 0.45 µm offers higher flow rates and is suitable for general clarification, HPLC sample prep, and removing visible particulates. Use 0.45 µm when sterility is not required.
Diameter depends on your filtration volume: 13mm for ≤1 mL, 25mm for 1–10 mL, 47mm for 10–200 mL, and 90mm for larger volumes. Match the disc to your filter holder or vacuum assembly.
PES, PVDF, and PTFE membranes can generally be autoclaved at 121°C. MCE and Nylon have limited autoclave tolerance. Always check the manufacturer specifications for your specific membrane and confirm compatibility with repeated sterilization cycles.
Surface filters (PTFE, Nylon, PES, MCE) capture particles at the membrane surface with a defined pore size. Depth filters (glass fiber) trap particles throughout the filter matrix. Depth filters handle higher particulate loads but have less precise cutoffs.