Skip to content

qPCR Wound, 100 reactions/unit

SKU OSK-WD-0100
Request a Quote or Call (858) 224-9100
Original price $4,500.00 - Original price $4,500.00
Original price
$4,500.00
$4,500.00 - $4,500.00
Current price $4,500.00
  • Ultra-High Sensitivity: Capable of detecting target concentrations as low as a few copies per reaction, enabling the detection of rare mutations or low-abundance transcripts with unparalleled sensitivity.

  • Exceptional Specificity: Incorporates proprietary primer and probe design algorithms and stringent reaction conditions to ensure minimal cross-reactivity and off-target amplification, resulting in highly specific and reliable results.

  • Rapid Turnaround Time: Optimized reaction protocols and thermal cycling conditions enable rapid amplification and detection, delivering results in significantly reduced assay times compared to conventional qPCR assays.

  • Multiplexing Capability: Designed for seamless multiplexing of multiple targets within a single reaction, maximizing throughput and efficiency without compromising sensitivity or specificity.

  • Integrated Quality Controls: Features built-in internal controls and reference genes to monitor assay performance, identify potential inhibitors or sample degradation, and ensure consistent and reliable results.

  • High Compatibility: Compatible with a wide range of qPCR instruments, ensuring easy integration into existing workflows and protocols without the need for specialized equipment or reagents.

  • Comprehensive Support and Training: Backed by comprehensive technical support, training resources, and expertise to assist users in optimizing assay conditions, troubleshooting issues, and maximizing the performance of the ampPCR panels.

These ampPCR panels incorporate optimized master mixes containing all essential components for the qPCR reaction, including DNA polymerase, dNTPs, buffer, and specific primers and probes tailored to the target of interest. The superior performance of ampPCR panels are attributed to their precise formulation, which ensures minimal variability, high efficiency, and broad dynamic range, enabling reliable detection and quantification of low-abundance targets across a wide range of sample concentrations. Additionally, the integration of advanced fluorescent detection chemistries and optimized thermal cycling protocols further enhances the sensitivity, specificity, and reproducibility of qPCR assays, making them indispensable tools for a myriad of applications in research and biotechnology.

These real-time PCR multiplexed tests ensure accurate and efficient pathogen detection and differentiation of its intended target(s).

Intended use: Available for research use only (RUO). Not for use in diagnostic procedures.

qPCR Panel FAQ's

Wound

Wound

How many reactions are in the kit?

100 reactions

What are the targets?

  • Acinetobacter Baumannii
  • Bacteroides Spp
  • Citrobacter Freundii
  • Citrobacter Braakii
  • Enterobacter Aerogenes
  • Enterobacter Cloacae
  • Escherichia Coli
  • Enterococcus Faecalis
  • Enterococcus Faecium
  • Klebsiella Oxytoca
  • Klebsiella Pneumoniae
  • Morganella Morganii
  • Psuedomonas Aeruginosa
  • Proteus Mirabilis
  • Proteus Vulgaris
  • Staphylococcus Aureus
  • Streptococcus Pyogenes

What is the shelf life of the kit?

The kit is valid for 12 months after the manufactured date and should be stored frozen at -20±5°C.

How many controls should I run on a plate for my clinical samples?

We recommend running at least 2 sets of positive and negative controls in case one set fails

A set refers to running a positive and negative control for every PCR mix included in a detection panel.

Why are there five reaction mixes?

Each of the 17 targets are split up into five reaction mixes. Patient samples and controls are run on each reaction mix so that all targets can be detected.

How many patient samples can I run on a single plate?

  • 96 well plate: 17 patient samples 
  • 384 well plate: 74 patient samples 
*Running 1 positive control and 1 negative control for each PCR mix. We recommend 2 sets but you only need 1 set to maximize your samples per plate.

What is the estimated run time of the method with this kit?

The method is estimated to be about ~60 minutes. Some thermal cyclers will vary in the duration of the method.

What is the Limit of Detection (LOD) for this kit?

This kit has a sensitivity as low as 1 copy/uL, but will vary depending on your thermal cycler.

What dyes should my thermal cycler be calibrated for?

FAM, JOE, ROX, Cy5

What is the stability of the prepared PCR plate?

It is best to prepare your plate and reagents as needed and not to let it sit at room temperature for extended periods of time. You should avoid storing the PCR reaction if possible; if it is needed, store the PCR reaction at -20°C for up to 30 minutes.

What are quantities of control and PCR mix?

  • Positive Control: 500uL 
  • Negative Control: 500uL 
  • PCR mix (5 total): 1.5mL each

How many freeze-thaw cycles can this kit do?

5 freeze-thaw cycles max.

Will this detection panel work for our lab if we only run a few samples per day?

Yes, we recommend aliquoting out the reagent based on your lab's sample volume to avoid unnecessary freeze-thaw cycles.

Get your results fast

Multiplexed Targets

Multiplexing enables the ability to analyze multiple targets in one reaction, saving time, reagents, and costs.

High Compatibility

Ready to use with QuantStudio 5, 7, 12, Roche LightCycler II, and BioRad CFX and Opus.

High Sensitivity

Achieve sensitivities as low as 1cps/ul. Give your lab the highest chance to catch every possible positive.

Get your results FAST

Get your results FAST

Optimize Operations with PCR-Driven Turnaround Time Reduction

Turnkey Validation

Our experienced validation engineer will be there with you to get your assay ready for market.

More About Validation