Skip to content

ampPCR Sexually Transmitted Infections qPCR Detection Panel, 100 Reactions/unit

SKU OSK-ST-0100

Specifications

Specification Value
Product Type STI qPCR Detection Panel
Reactions 100 reactions
Application qPCR
Test Panel 12 targets including HPV, Chlamydia trachomatis, Neisseria gonorrhoeae, and others
Purpose Detection of sexually transmitted infections
Storage Store at -20°C
Sensitivity
1 copy/uL
Time to Results
45-55 minutes
Compatibility

Including but not limited to 96 and 384 versions of
- QuantStudio 5, 7 and 12
- Roche LightCycler II
- BioRad CFX and Opus

    Description

    At present, sexually transmitted diseases (STDs) make up the most common group of infectious diseases that must be reported in the majority of countries. Their incidence is elevated, and more than 20 pathogenic micro organisms are known to be transmitted by sexual contact, with Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis and Mycoplasma (genitalium and hominis) being the most common.

    Sexually transmitted diseases (STD) are a major cause of infertility, long-term disability, ectopic pregnancy, and premature birth. The product is intended for use by qualified laboratory personnel well trained in nucleic acid amplification techniques and in vitro diagnostic procedures. Positive results do not rule out co-infection with other pathogens. Negative results do not preclude microbial infection and should not be used as the sole basis for patient management decisions. Test results must be combined with clinical observations, patient history, and epidemiological informat

    Targets:

    • Mycoplasma hominis
    • Chlamydia trachomatis
    • Gardnerella vaginalis
    • Trichomonas vaginalis
    • Ureaplasma parvum serovar
    • Ureaplasma urealyticum
    • Mycoplasma genitalium
    • Neisseria gonorrhoeae

    Comprehensive Detection: Covers a broad range of STIs, ensuring a comprehensive scan of potential infections.

    Efficient: Contains material for 100 reactions, ideal for large-scale testing.

    Highly Sensitive and Specific: Employs qPCR technology, recognized for its high sensitivity and specificity in pathogen detection.

    Versatile: Suitable for clinical laboratories, research institutions, and public health settings.

    The STI qPCR Detection Panel is a powerful tool in the fight against sexually transmitted infections. Covering a broad spectrum of 12 STIs. This kit ensures you won't miss a thing.

    Efficient and effective, the kit is designed for 100 reactions, making it a cost-effective solution for mass screenings or research purposes. Thanks to its use of the highly sensitive and specific qPCR technology, you can trust the results to guide your next steps.

    Whether you're a clinical laboratory, a research institution, or a public health organization, our STI qPCR Detection Panel is the perfect solution for STI detection. Note: For optimal performance, ensure the kit is stored at -20°C when not in use.

    Frequently Asked Questions

    How many reactions are in the kit?

    100 reactions


    What is the shelf life of the kit?

    The kit is valid for 12 months after the manufactured date or until the expiration date and should be stored in a -20°C storage.


    How many controls should I run on a plate for my clinical samples?

    We recommend running at least 2 sets of positive and negative controls in case one set fails (a set refers to running a positive and negative for ALL oligo mixes).


    How many patient samples can I do in a single run?

    96 Well Plate: 44 Patient Samples (assuming you are running 2 sets of positive and negative controls)
    384 Well Plate: 188 Patient Samples (assuming you are running 2 sets of positive and negative controls and filling all the plate wells)


    What is the estimated run time of the method with this kit?

    The method is estimated to be about ~60 minutes. Some thermal cyclers will vary in the duration of the method.


    What is the LOD for this kit?

    This kit has a sensitivity as low as 1 cp/uL, but will vary depending on your thermal cycler.


    What dyes should my thermal cycler be calibrated for?

    FAM, JOE, ROX, Cy5


    What is the stability of the prepared PCR plate? Am I able to store it in a freezer after making the reaction?

    It is best to prepare your plate and reagents as needed and not to let it sit at room temperature for extended periods of time. You should avoid storing the PCR reaction if possible; if it is needed, store the PCR reaction at -20°C for up to 30 minutes.


    What are quantities of control and PCR mix?

    Positive Control: 100 uL
    Negative Control: 100 uL
    STI(1-2) PCR Mix: 1.5mL each tube

    Turnkey validation

    Comprehensive solution for your lab's validation project. Reduce launch time by 80% or more.

    Schedule a Consultation

    Automation Compatible

    Ready to use with QuantStudio 5, 7, 12, Roche LightCycler II, and BioRad CFX and Opus

    High Sensitivity

    Detects 1 copy of viral RNA per microliter of transport media

    Get results. Fast.

    Get results. Fast.

    Learn more

    Compare products

    {"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

    Select first item to compare

    Select second item to compare

    Select third item to compare

    Compare