Skip to content

ampPCR Wound qPCR Detection Panel, 100 Reactions/unit

SKU OSK-WD-0100

Specifications

Specification Value
Product Type Wound qPCR Detection Panel
Reactions 100 reactions
Application qPCR
Purpose
Storage Store at -20°C
Sensitivity
1 copy/uL
Time to Results
45-55 minutes
Compatibility

Including but not limited to 96 and 384 versions of
- QuantStudio 5, 7 and 12
- Roche LightCycler II
- BioRad CFX and Opus

    Description

    This product is designed to quickly manage skin and soft tissue infections, avoiding delays in diagnosis and preventing infections from progressing. The product is intended for use by qualified laboratory personnel well trained in nucleic acid amplification techniques and in vitro diagnostic procedures. Positive results do not rule out bacterial infection or co-infection with other pathogens. Negative results do not preclude microbial infection and should not be used as the sole basis for patient management decisions. Test results must be combined with clinical observations, patient history, and epidemiological information.

    Targets:

    • Acinetobacter baumannii
    • Bacteroides spp.
    • Citrobacter freundii
    • Citrobacter braakii
    • Enterobacter aerogenes
    • Enterobacter cloacae
    • Escherichia coli
    • Enterococcus faecalis
    • Enterococcus faecium
    • Klebsiella oxytoca
    • Klebsiella pneumoniae
    • Morganella morganii
    • Psuedomonas aeruginosa
    • Proteus mirabilis
    • Proteus vulgaris
    • Staphylococcus aureus
    • Streptococcus pyogenes

    The Wound qPCR Detection Panel is specifically designed to detect and identify multiple wound-related pathogens. It targets specific genes associated with these pathogens, providing a comprehensive analysis of wound infections.

    Utilizing the sensitive and specific Reverse Transcription Polymerase Chain Reaction (qPCR) method, this detection panel ensures accurate and reliable results. It can detect even low levels of pathogens, allowing for early and precise identification of wound infections.

    The Wound qPCR Detection Panel allows for the analysis of up to 100 reactions in a single run, optimizing laboratory efficiency. It provides a time-saving solution for wound pathogen detection without compromising on result quality.

    This detection panel is compatible with standard RT-PCR instruments, making it accessible to a wide range of laboratories. It integrates seamlessly into existing workflows, ensuring easy implementation without the need for specialized equipment.

    The panel includes positive and negative controls, allowing for validation and quality control of the assay. These controls help to ensure the accuracy and reliability of the test results, providing confidence in the detection process.

    The Wound qPCR Detection Panel is a cutting-edge solution for accurate and efficient detection of wound-related pathogens. Designed to cater to the specific needs of wound infection analysis, this panel utilizes the powerful qPCR method to identify multiple pathogens associated with wound infections.

    With its high sensitivity and specificity, the Wound qPCR Detection Panel offers reliable results, even for low-level pathogen detection. This enables healthcare professionals to make informed decisions and provide timely treatment for patients with wound infections.

    Featuring a generous capacity of 100 reactions per run, this detection panel optimizes laboratory efficiency by allowing simultaneous analysis of multiple samples. It is compatible with standard qPCR instruments, facilitating easy integration into existing laboratory workflows.

    The inclusion of positive and negative controls within the panel ensures assay validation and quality control. By using these controls, laboratories can verify the accuracy and reliability of the test results, enhancing confidence in the detection process.

    Manufactured under ISO 13485 quality management system, the Wound RT-PCR Detection Panel meets the highest standards of quality and regulatory compliance. It complies with applicable regulatory requirements, providing assurance in its performance and reliability.

    Choose the Wound RT-PCR Detection Panel for comprehensive and precise detection of wound-related pathogens. With its advanced technology and user-friendly design, it empowers healthcare professionals in their efforts to diagnose and manage wound infections effectively.

    Frequently Asked Questions

    How many reactions are in the kit?

    100 reactions


    What is the shelf life of the kit?

    The kit is valid for 12 months after the manufactured date or until the expiration date and should be stored in a -20°C storage.


    How many controls should I run on a plate for my clinical samples?

    We recommend running at least 2 sets of positive and negative controls in case one set fails (a set refers to running a positive and negative for ALL oligo mixes).


    How many patient samples can I do in a single run?

    96 Well Plate: 15 Patient Samples (assuming you are running 2 sets of positive and negative controls)
    384 Well Plate: 72 Patient Samples (assuming you are running 2 sets of positive and negative controls and filling all the plate wells)


    What is the estimated run time of the method with this kit?

    The method is estimated to be about ~60 minutes. Some thermal cyclers will vary in the duration of the method.


    What is the LOD for this kit?

    This kit has a sensitivity as low as 0.2 cps/uL, but will vary depending on your thermal cycler.


    What dyes should my thermal cycler be calibrated for?

    FAM, JOE, ROX, Cy5


    What is the stability of the prepared PCR plate? Am I able to store it in a freezer after making the reaction?

    It is best to prepare your plate and reagents as needed and not to let it sit at room temperature for extended periods of time. You should avoid storing the PCR reaction if possible; if it is needed store the PCR reaction at -20°C for up to 30 minutes.


    What are quantities of control and PCR mix?

    Positive Control: 100uL
    Negative Control: 100uL
    WP(1-5) PCR Mix: 1.5mL each tube

    Turnkey validation

    Comprehensive solution for your lab's validation project. Reduce launch time by 80% or more.

    Schedule a Consultation

    Automation Compatible

    Ready to use with QuantStudio 5, 7, 12, Roche LightCycler II, and BioRad CFX and Opus

    High Sensitivity

    Detects 1 copy of viral RNA per microliter of transport media

    Get results. Fast.

    Get results. Fast.

    Learn more

    Compare products

    {"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

    Select first item to compare

    Select second item to compare

    Select third item to compare

    Compare